Agilent HP 16550A Timing Analysis Module
DESCRIPTION
The 16550A 100MHz State and Timing Analysis Module provides a conventional timing-analysis rate of 250/500MHz, a transitional timing-analysis rate of 125/250MHz and a glitch timing-analysis rate of 125MHz. It has 102 channels per card and 204 channels per timebase.
Features
* Assign channels to capture state and timing data without moving probes
* Advanced trigger macros capture elusive problems
* Capture up to 204, 4M deep channels simultaneously
* Conserve acquisition memory with transitional timing by storing samples only when data changes
* Enhance troubleshooting with flexible display modes