Menu

Waters

Ref : 1771376-18-CP
Condition : Used
Manufacturer : Waters
Model : -
Short Description : -
Year(s) : -
Quantity : 1
Location : Seller or machines location:
AMERICA North (USA-Canada-Mexico)
Last check : 12 Feb. 2020

Waters 2414 Refractive Index (RI) Detector

Waters 2414 Refractive Index (RI) Detector is designed for high-performance liquid chromatography (HPLC) applications. It provides sensitivity, stability, and reproducibility for the analysis of components with limited or no UV absorption. The solution-centered design combines with Alliance or Breeze HPLC Systems for RI-based HPLC and GPC applications.

Waters 2414 RI Detector provides solutions for preparative and analytical applications including alcohol, sugar, saccharide, fatty acid, and polymer analysis.

Features:
• Low dispersion volume for high-speed GPC and narrowbore column chromatography from 0.1 to 10 mL/min
• Thermally isolated optics bench for temperature stability and performance reproducibility
• Save solvent and maintain stability with convenient recycle valve
• Diagnostics and simplified design and control options for easy maintenance and everyday use
• Circuitry and software in the detector’s thermally isolated optics bench provide a sensitive, stable signal response to changes in refractive index independent of ambient temperature changes
• Auto-zero, auto-purge, and LED-displayed diagnostic programming enable unattended operation and to simplify methods development
Condition Specification
RI Range 1.00 to 1.75 RIU
Measurement Range 5 x 10-4 RIU
7x 10-9 RIU
Flow Rate 0.1 to 10 ml/Min
Noise +1.5 x 10-9 RIU, in RIU mode (Hamming filter TC = 2, ambient temperature 23 to 25°C
(+2°C/hr), 1 mL/min. 100% water.
+3.0x° RIU, in 410 mode (RC filter TC=1, ambient temperature 23 to 25°C (+2°C/hr), 1 mL/min. 100% water
Drift 2.0 x 10-7 RIU/hr
RIIU-FS Settings (RIU mode) 1.0 x 10 -6 to 5.0 x 10 -4 RIU
Sensitivity Settings (410 mode) 1,2,4,8,16,32,64,128,256,512,1024
Time constant Filter Settings 0.0 to 5.0 seconds (Hamming)
0.0 to 10.0 (RC)
0.2, 1,3,10 seconds (RC under software data control)
Analog Outputs -2.0 to 2.0V
Temperature control Internal oven: 30 to 55°C (86 to 131°F)
One external column heater:
Ambient to 150°C (302°F), steel

This refurbished Waters 2414 Refractive Index (RI) Detector is in great condition.

Other machines similar to Waters

1
Location : AMERICA North (USA-Canada-Mexico)
1
Location : AMERICA North (USA-Canada-Mexico)
1
Location : AMERICA North (USA-Canada-Mexico)