Siemens Somatom Emotion 16
AMERICA North (USA-Canada-Mexico)
The Siemens SOMATOM Emotion 16 CT system combines efficiency,
leading clinical applications, and simple workflow to bring better clinical outcomes
and greater financial success.
The Emotion 16 offers high-quality images with menial life-cycle cost,
and reconstruction of up to 16 images per second.
This system is very compact, needing only 18 square meters of space,
designed with a 70 cm aperture, a 50 cm scan field and a patient table
that can hold patients up to 440 pounds.
Perform routine exams as well as detailed and high resolution exams
with the Siemens Somatom Emotion 16.
Clinical Applications:
Abdominal
Adult Cardiac
Functional Imaging
Pediatrics
Pelvis
Spinal
Thoracic
Features:
Smallest Focal Spot
Multislice UFC Detector
1472 Effective Detector Channels
Small Gantry Geometry
CARE Dose4D
Significant Dose Reduction and Image Quality Improvement with IRIS*
16-slice acquisition
A wide range of clinical applications
Fast and efficient with 0.6 second rotation time
0.75 or 1.5mm slices per rotation in less than 20 seconds
Small diagnostic detail for acquisition
105-millisecond temporal resolution for a clear depiction of blood vessels
Scan any anatomy with a single breath hold
Pathology can be seen from any perspective
Benefits:
Most economical 16 slice CT and smallest footprint
Increased efficiency with linked database, fast reconstruction, WorkStream 4D,
and dose reduction with CARE Dose 4D
Less downtime with faster installation and reduced scheduled maintenance requirements
More than 98% of the materials used can be returned to the flow
of recyclable materials
CT Technology:
syngo LungCARE CT with NEX (Nodule Enhanced Viewing)
syngo Colonography with PEV (Polyp Enhanced Viewing)
Technical Specifications:
Gantry
Gantry Generation: 3rd
Slipring: Low voltage
Aperture: 70 cm
FOV: 50 cm (standard), 70 cm (optional)
Tilt range: ±30 degrees
Type of positioning lights: Laser
Accuracy of positioning lights: ±1 mm
Focus-detector distance: 940 mm
Patient Couch/ Table:
Couch top material: Carbon fiber
Couch top length and width: 222 x 43 cm
Horizontal movement range: 153 cm
Horizontal movement speeds: 1-100 mm/sec
Accuracy/reproducibility of table positioning: ±0.25 mm (Horizontal movement)
Scannable horizontal range without table top extension: 153 cm
Scannable horizontal range with tabletop extension(s): 153 cm
Vertical movement range out of gantry: 45-83 cm
Vertical movement range in gantry: 64-83 cm
Minimum couch top height outside gantry: 45 cm (Vertical movement)
Maximum weight allowed on couch: 200 kg (440 lbs)
Maximum weight on couch which still achieves stated performance specifications: 200 kg
X-Ray Tube:
Type/Make: Siemens Dura 422 MV Siemens Straton
Focal spot size(s) quoted to (X-RAY TUBE): 0.5 mm x 0.8 mm
IEC 336/93 standard (X-RAY TUBE) 0.7 x 0.8
Settings at which focal spot change automatically; small changes
kW = kV x mA / 1000: up to 28 kW ; large up to 45 kW
Total filtration (inherent + beam shaping filter) at central axis (mm Al equivalent) (X-RAY TUBE) 6.3 (140kV)
Anode heat capacity (MHU): 5
Maximum anode cooling rate (kHU/min): 810
Method of cooling (X-RAY TUBE) Oil to air
Guaranteed tube life: 200,000 scan seconds
Detector type: Solid state (Ultra Fast Ceramic)
Maximum number of simultaneously acquired data sets (no. of slices): 16
Number of detectors per row (Maximum anode cooling rate): 736 (1472 channels)
Number of elements along z-axis (Maximum anode cooling rate): 24
Effective length of each element at isocentre: 16 x 0.6 mm, 8 x 1.2 mm
Total effective length of detector array at isocentre: 19.2 mm
Option for more slices / rotation (Maximum anode cooling rate): Yes
Generator/Power:
X-ray generator: VAC Power Needed
Type: High frequency
Location: Rotation assembly (Composition)
Power rating – kV settings available (Maximum weight allowed on the couch): 50, 80, 110, 130 kW
mA range and step size (Weight-bearing properties) 20-345(1mA steps)
Maximum mA allowed for each kV (Weight bearing properties) 80 kV: 345 mA
Main Console:
Monitor/ Screen Size: 19 inches
Number of monitors at the console (functions of each if > 1) (Image monitor)
Up to 6 (shared database)
Image area matrix dimensions: 1024 x 1024
Usual range of CT number displayed (HU) (Image monitor) (-10,240 to 30,710 if metal implants)
The accuracy of distance measurements in x-y plane depends on pixel size (mm)
Weighted CTDI (CTDIw or CTDIvol) displayed on console
Dose Length Product (DLP) displayed on console (Dose information)
Geometric Efficiency displayed on the console when 70% for all collimations
Control methods: Mouse, keyboard