Siemens Acuson Cypress CV Ultrasound
AMERICA North (USA-Canada-Mexico)
Introducing the Siemens Acuson Cypress CV Ultrasound System.
The ACUSON Cypress™ cardiovascular system PLUS
delivers advanced ergonomic design and
premium cardiovascular performance in a fully digital,
portable, hand-carried unit.
The Cypress system features comprehensive echocardiography
and vascular applications, and is designed to
work in all of your busy clinical environments –
from small private office or hospital echo lab to
the patient bedside, emergency room, operating suite,
and critical care unit.
Applications
Adult and pediatric transthoracic echocardiography (TTE)
Multiplane transesophageal echocardiography (TEE)
Intracardiac echocardiography (ICE) with ACUSON AcuNav™ ultrasound catheters
Peripheral vascular
Abdominal vascular
Comprehensive measurements and calculations as
well as report and analysis packages,
including integrated stress echo
Native Tissue Harmonic portable Imaging ,
Color Doppler, PW, CW, B-Color, M-Mode, ECG unit.
It weighs 18 pounds. Manufactured by Siemens.
Used for Cardiology (2DEcho),
vascular ( upper/lower extremities Doppler arterial,
venous and carotid). Network ready.
Features
Cardiac / Vascular
Lightweight
Portable
Harmonic Imaging
High frame rate color flow mapping
Digital image management
DICOM capability
Phased array capability
Color doppler, Color angio and B-color
M-mode
128 channel digital beamformer
PW/CW Doppler
AEGIS integrated stress echo
7L3 Transducer Details
6.6 – 5.4 MHz Linear Transducer for Vascular Imaging
B-Mode Frequencies 5.4 – 6.6 MHz
Doppler Frequency 4.3 MHz
Number of Elements 128
Lens Dimensions 44 mm x 9 mm
Field of View 99 mm
Array Length 38.4 mm
Wide bandwidth linear transducer
High performance vascular capabilities
High detail dynamic range and contrast resolution
User selectable 2D frequencies: 5.4 MHz and 6.6 MHz
2D beam steering
Low flow detection
Excellent ergonomics and flexible cable
Single probe solution
2D, Color (velocity and energy), PW
3V2c Transducer Details
3.6 – 1.8 MHz Vector Transducer for Adult Cardiac
B-Mode Frequencies 1.8 – 3.6 MHz harm., 2.7 MHz fund.
Doppler Frequencies 2.1 – 2.7 MHz
Number of Elements 64
Lens Dimensions 24 mm x 18 mm
Field of View 271 mm
Array Length 16.6 mm
Wideband phased array transducer with
a Cypress system type connector
2 – 4 MHz frequency range
High detail, contrast and temporal resolution
High sensitivity in color and spectral Doppler velocity modes
High frame rates in 2D and Color Doppler velocity mode
Superior ergonomics for comfort and access
2D, Harmonics, Color (velocity and energy), PW, CW, M-Mode