Regenus 2030 vII
United Kingdom
Relox Regenerative Thermal Oxidizer with Heat Exchanger
Key data:
Nominal 30 000 Nm3/h; max 40 000 Nm3/h
Heat thermal oil exchanger included, 1000kW
Clean air emissions: max C 20 mg/Nm3; CO 100 mg/Nm3, NOx 100 mg/Nm3
Gas consumption: ~60 m3/h at no solvent and max volume; ~40 m3/h at 1g/Nm3 and max
Volume; ~20 m3/h at 2g/Nm3 and max volume
Heat recovery ~95%
Building method: 3-separate-chamber-plant
Oxidation temperature: ~800-900 C
Burning chamber temperature max: 1000 C
Type of solvent: ethanol ~30%, ethyl acetate ~70%
Solvent Concentration: min 5% LEL, indicates lower level of burning without gas, max 25% LEL
Heating value of solvent mix: approx. 7000kcal/kg
Min gas consumption: 4.75 m3/h
Power supplies & consumption
Gas: natural gas, Hu=10 kW/Nm3
Gas pressure: 80-200 mbar (flow pressure)
Gas burner max capacity: 800 kW
Electrical power: 400 V / 50 Hz
Electrical consumption ~58 kW
Installed electrical power: 75 kW
Pressurized air: 6 bar, dus-t, oil- and water free / dew point +30C
Pressurized air consumption: 16 m3/h
Dimensions (w/o process fan and hot oil heat exchanger)
Length: 10.2m x Width: (w/o burner stage) 3.3m x Height 5.7m
Weight ~45t