Imaging programs
Standard: Basic panoramic programs Standard panoramic
Lateral TMJ (closed & open)
PA TMJ (closed & open)
PA sinus
Standard Child (Paediatric) mode for each standard and optional program to reduce the dose
Optional Horizontal and vertical segmenting for panoramic program
Optional True Bitewing

Optional:
Advanced panoramic programs Interproximal panoramic
Orthogonal (perio) panoramic
Lateral-PA TMJ
Lateral multiangle TMJ
PA multiangle TMJ
PA linear sinus
Lateral sinus
Optional: Tomography programs Digital linear tomography in digital unit
True linear tomography or Linear tomography in film unit

Technical data
Generator Constant potential, resonance mode high frequency
80–150 kHz
X-ray tube D-054SB-P
Focal spot size
0.5 x 0.5 mm (IEC 336)
Total filtration min. 2.5 mm Al equivalent
Anode voltage 50–84 kV
Anode current 0.5–16 mA DC

Exposure time
Pan 2.7–16 s
Scanning ceph 6.4–9.9 s
Planmeca ProCeph 0.1–0.8 s
Tomo 3 s / frame

SID
Pan 500 mm (19 in.)
Ceph 163–170 cm (64–67 in.)

Magnification
Pan constant 1.2
Ceph 1.08–1.13
CCD pixel size 48 µm
Image pixel size 48/96/144 µm selectable

CCD active surface
Pan 6 x 147 mm
Ceph 6 x 295 mm

Resolution (digital)
Pan max. 9 lp/mm
Ceph max. 5.7 lp/mm

Image field (digital)
Pan 14 x 30 cm (5.5 x 12 in.)
Ceph 24/27 x 18/30 cm (9/10.6 x 7/11.8 in.)

File size, un­compressed (digital)
Pan 4–33 MB
Ceph 7–16 MB

Line voltage 100–240 V, 50 or 60 Hz
Regulation Automatic, ±10 %
Line current 8–16 A
Colour White (RAL 9016)

Physical space requirements

Width
Planmeca ProMax 2D 96 cm (38 in.)
Planmeca ProMax 2D with cephalostat194 cm (76 in.)

Depth
Planmeca ProMax 2D 125 cm (49 in.)
Planmeca ProMax 2D with cephalostat 125 cm (49 in.)

Height*
Planmeca ProMax 2D 153–243 cm (60–96 in.)
Planmeca ProMax 2D with cephalostat 153–243 cm (60–96 in.)

Weight
Planmeca ProMax 2D 113 kg (lbs 248)
Planmeca ProMax 2D with cephalostat 128 kg (lbs 282)

Minimum operational space requirements
Width
Planmeca ProMax 2D 150 cm (59 in.)
Planmeca ProMax 2D with cephalostat 215 cm (85 in.)

Depth
Planmeca ProMax 2D 163 cm (64 in.)
Planmeca ProMax 2D with cephalostat 163 cm (64 in.)

Height*
Planmeca ProMax 2D 243 cm (96 in.)
Planmeca ProMax 2D with cephalostat 243 cm (96 in.)