Philips Veradius Mobile C Arm With Flat Detector
OCEANIA
The Philips Veradius Unity provides crucial guidance,
high-quality images, and accurate positioning to
help increase first-time-right results.
It increases confidence during complex vascular,
cardiac, and orthopedic procedures.
ClearGuide combined with color coding on the C-arm speeds up
positioning making spinal surgery and other procedures that
require frequent position changes more pleasant for clinicians.
Philips Veradius Unity C Arm Specifications:
General
Brand: Philips
Model: BV Pulsera C Arm
Category: X-Ray Equipment
Incredible image quality.
Dual 19” color LCD monitors.
Flat Detector
Angulation: + 90 / - 50 Degree
Lowest lateral position: 102.7 cm/ 40.4 inch
C-Arm Stand
Height: 66.4 – 85.7” (168.7 – 217.7 cm)
Width: 32.1” (84.1 cm)
Depth: 76.9 – 108.6” (195.6 – 275.8 cm)
Weight: 757 lbs. (346 kg)
Mobile View Station
Height: 73.6” (186 cm)
Width: 37.1” (94.3 cm)
Depth: 27.6” (70.1 cm)
C-Arm Movements
Angulation: 140° rotation (+90/-50°) offers a maximum of
projection flexibility
Motorized height movement: 19.3” (49 cm)
Longitudinal Movement: 7.0” (20 cm)
Panning Movement (Swivel): ±10°
Rotation: ±200°
Lowest Lateral Position: 40.4” (201.7 cm)
Source to Image Distance (SID) 39.1” (99.3 cm)
Free Space in C-Arm: 30.4” (77.2 cm)
C-Arm Depth: 29” (73 cm)
Parallel Movement: Dedicated parallel movement with
rear-wheel steering, for easy positioning along operating table.
C-arm stand length: 77.2” (196 cm)
Mobile View Station Monitors
Resolution: 1280 x 1024 pixels
Maximum light output: 650 cd/m2
Minimal Contrast Ratio: 1/400
Contrast Ratio: >700:1
Viewing Angle: 170° in the horizontal and vertical directions.
Touchscreen: Offers easy access to post-processing of acquired
images, patient demographics as well as PACS (left monitor)
Monitors: Two 19” high-brightness color LCD monitors for
diagnostic image quality display
X-Ray Generator
Monoblock
High tension transformer
Frequency: 80 kHz
X-Ray Tube
Rotating Anode
High-Power generator
X-Ray
Tube Type: Rotating Anode
Nominal X-ray tube voltage: 120 kV
Nominal focal spot values: 0.3 and 0.6 mm
Max. Anode Heat Content: 315 kHU
Max. Heat Dissipation: 73 kHU/min
Cooling Method: Active oil-circulation cooling
Inherent filter: 1.0 mm AI. equivalent
Integrated Beam Filter: 3.0 mm Ai +0.1mm Cu
Total Beam Filtration: 6.75 mm AI. eq
Operating Values With Pulse Fluoroscopy
kV range: 40-120 kV
mA Peak Range: 1-60 mA
Pulse Width: 5.6-44 ms
Pulse Rate: 4-8-15-optional 30
Operating Values With Exposure Runs
kV Range: 40-120 kV
mA Peak Range: 1-60 mA
Pulse Width: 9.3 178 ms
Pulse Rate: 4-8-15-optional 1-2-30
Operating Values With Single-Shot Exposure
kV Range: 40-120 kV
mA Peak Range: 2-125 mA
Time Range: 100 and 165 ms
X-Ray Collimation
Full lead shutters can be rotated and moved independently.
Automatic Shutter Positioning (ASP) automatically positions shutters for optimal image quality.
Flat Detector
Flat Detector Frees up valuable workspace around the
patient during challenging procedures.
Integrated Laser
The integrated laser in the flat detector can be activated and
deactivated at the touch of a button.
635 nm
Max. Output: