Maquet Alphastar
EUROPE (Western and Northern)
The Maquet Alphastar operating table is
cutting-edge medical equipment used in
operating rooms for various surgical procedures.
It is renowned for its versatility,
offering a wide range of positions and
adjustments to meet the specific needs of each surgery.
Featuring features such as electrical positioning,
radiolucency and high load capacity,
the Maquet Alphastar table ensures both patient safety and
comfort as well as easy handling for
medical staff. Its ergonomic design and reliability make it
a popular choice in healthcare facilities around the world.
• Length without accessories : 1,300 mm
• Length with headrest and 2 extension plates : 2095 mm
• Width : 520 mm
• Width with accessory rails : max. 590mm
• Height (without mattress) : 685 - 1125 mm
• Height (without mattress) : 598 - 950 mm
• Weight : approx. 300kg
• Head tilt downwards : max. 30°
• Feet tilt downwards : max. 30°
• Left/right slope : max. 18°
• Mount NORMAL folder : max. 68°
• Lower NORMAL backrest : max. 25°
• Mount REVERSE folder : max. 80°
• Lower backrest INVERSE : max. 105°
NORMAL patient orientation
• Flex position : max 25°
• Tilt, legs down : 12.5°
• Lower NORMAL backrest : max. 12.5°
• Reflex position : 60° max.
• Tilt, head down : 25°
• Lower NORMAL backrest : max. 35°
REVERSE patient orientation
• Flex position : max. 60°
• Tilt, head down : 30°
• Lower short backrest/REVERSE : 30°
• Reflex position : 70° max.
• Inclination, ambes downwards : 30°
• Mount short backrest/REVERSE : 40°
Electrical data
Nominal voltage :
• 100/110-115/127
• 200/220/230-240VAC
• Frequency : 50/60 Hz
• Power consumption : 400 VA maximum
• Protection class : II
• Category of use : Туре В
• Leakage current meets the requirements of CEl 601-1 for
patient leakage current according to
CF IP X4* IPS** SELV*** DC 24V
How to use :
• int. 10 minutes. ON/ 20 min. STOP
• For patients between 225 kg and 270 kg : 2 min. ON/ 120 min. STOP
• Explosion-proof protection when operating on batteries
• When operating on mains power ,
the operating table must not be used in areas at
risk of explosion , AP-M.
Accumulators :
• Type A512C / 15SR
• 2 12 V / 15 Ah accumulators
The Maquet AlphaStar Surgical Table ,
featuring an electrically controlled hydraulic drive,
provides essential table functions, from table position to
automatic forward-reverse movement to invert mode.
The AlphaStar can be modified to meet the needs of
any surgical discipline in just a few quick steps.
Ideal for ensuring fluidity of work in the operating room .