Heuft InLine IXs reflexx, Empty Bottle Inspector
EUROPE (Western and Northern)
Technical details
Output: Up to 46,000 bottles/hour
Missing components
Thread blow-off (must be added if required)
Controls
Monitoring of the incoming bottle flow (optional)
Output of a stop signal in the event of incorrect bottle dimensions
Inspection of the bottle base, mouth sealing surface and thread
Inspection of the inner and outer side wall
Detection of conductive liquids (e.g. lye) and residual liquids (oils, paints) using IR technology
Rejection of faulty containers or output of a rejection signal
Scope of delivery
Spectrum TX conveyor control unit
Measuring bridges for inlet control and rejection with height adjustment
2 x Delta K rejection units
Air conditioning unit
Various spare parts (pulleys, belts)
Documentation and training documents (German)
Transponder for test bottles