Technical data:
Amount of material: 36 dry material weighers
Humidity: 12%.
Drying time: max. 36h
Heating phase (0° - 100°C): approx. 1h
Cooling phase: approx. 1h
Dimensions & weight:
External dimensions: W x L x H: 5250 x 13820 x 3800
Drying room: W x L x H: 3800 x 12000 x 1800
Total weight approx. 17t
Performance data
Process temperature: max. 145°
Surface temperature: max. 60° at the outer plating
circulating air volume: approx. 20m³/s (4 radial built-in fans with 5m³/s each)
average velocity in the free process area: 0.4m/s
exhaust air volume: total max. 0.8 m³/s = supply air volume
Heating: four heat exchangers in circulation system with three gas burners each 80 kW max.
Natural gas H, continuously controlled, exhaust gas separately into the open air
gas burner with safety and control devices, heat output control & combustion air fan
control: switch cabinet with cable base approx. 1200 x 2000 x 400mm
program controller, main switch, fuses and control element
floor profile: U-profiles along the kiln axis to support the 36 weighers (one U-rail each as guiding track)
Connection data
Power: 400V / 50Hz / approx. 75kW
Gas: Natural gas H DVGW AB 260 & 80mbar / max. 25m³/h i.N.
Supply air: room air max. 0,8m³/s i.N.
Compressed air: 6 bar / max. 5m³/h i.N. - compressed air quality min. class 2
Exhaust air: process air humid, max. 0,8m³/s i.N. max 145°C /+2mbar
Exhaust gas: burner exhaust gas max. 0,08m³/s, max. 400°C / 0... + 2mbar