Menu

Generic e700 Ventilator

Ref : 2636202-14-W
Condition : Used
Manufacturer : Generic
Model : e700 Ventilator
Year(s) : -
Quantity : 1
Location : Seller or machines location:
AMERICA North (USA-Canada-Mexico)
Last check : 07 Nov. 2024

O-Two Medical Technologies e700 Ventilator
No Pole Clamp
The e700 ventilator ushers in a “new era” in
controlled ventilation for resuscitation and
patient transport!
These electronically controlled,
pneumatically powered ventilators provide a
range of ventilation solutions for all types of
patient requirements and all levels of
pre-hospital and in-hospital healthcare professionals.

SPECIFICATIONS
DEVICE CLASS PER MDD II b
CLASSIFICATION
PER IEC60601-1
Protection against electric
shock Class II
Protection against electric
shock Type BF
Protection against water IP X4
POWER SOURCE Compressed Oxygen, 45 to 87 PSI (3-6 Bar)
CIRCUIT CONTROL SOURCE Electric
VENTILATION MODES A/C (VCV,PCV), SIMV w/ PSV, BiLVL w/ PSV, CPAP w/ PSV,
Mask CPR and Intubated CPR
SUPPORTING VENTILATION PSV: 0, 4-35 cmH2O (± 10% or ± 2 cmH2O)
VENTILATION RATE 5 – 60 (± 10% or ± 1BPM)
MINUTE VOLUME (L) Calculated
TIDAL VOLUME (ML) 50 – 2000 ± (4ml + 15%) BTPS *
TIDAL VOLUME IN CPR MODE (ML) 50 - 1400 ± (4ml + 15%) BTPS *MAXIMUM DELIVERED FLOW (L/MIN) 100 – 120
MANUALLY TRIGGERED VENTILATION Yes, set flow rate or pressure will be delivered during I time
then Inspiratory hold
MAXIMUM INSPIRATORY HOLD TIME 6 sec.
I:E RATIO 1:4 – 3:1 (± 20%)
PEEP (CM H2O) 0,4-20 (± 10% or ± 2 cmH2O)
PSV OFF, 4 – 35 (± 10% or ± 2 cmH2O)
CPAP (CM H2O) 4-20 (± 10% or ± 2 cmH2O)
O2 (%) 60 or 100 (± 15%)
PMAX (CM H2O) 10 – 80 (± 10% or ± 2 cmH2O)
PMIN (CM H2O) 0 – 20 (± 10% or ± 2 cmH2O)
PCV (CM H2O) 4-50 (± 10% or ± 2 cmH2O)
TI (SEC.) 0.2 – 9 (± 20%)
TRIGGER SENSITIVITY (L/MIN) 1 -15, or 2 cmH2O below baseline in CPAP mode only
INHALATION PRESSURE (CM H2O) 4-50 (± 10% or ± 2 cmH2O)
PRESSURE VENTILATION TERMINATION 20% - 80% of max. Flow
APNEA BACK UP TIME (SEC.) 10-60 (± 0.5s)
BATTERY OPERATING TIME AT ROOM
TEMPERATURE (HRS.)
> 18 hrs for default settings (Data obtained using fully
charged new battery)
ALTITUDE COMPENSATION up to 4000m (13000 feet)
BATTERY HOT SWAP No
BUILT-IN BATTERY CHARGER Yes
AC/DC POWER SUPPLY 100-240 VAC/ 19 VDC, 4.74 A
PATIENT CIRCUIT O-Two Electronic Ventilator Circuit
MOUNTING BRACKET
Mounting brackets for road ambulance and
mobile setting
DISPLAY 4.3" Color TFT
LIVE MONITORING Mve,Vte,Paw(AV),PAW(Peak), Rate (bpm), Battery level
REAL TIME WAVEFORM Pressure or Flow
DAY/NIGHT DISPLAY MODE Yes
PARAMETER SETTINGS Control Selection Knob
LOCK KEY FUNCTION Yes
PAUSE FUNCTION Yes
NOISE LEVEL IN NORMAL USE Less than 65 dBA
ALARMS (VISUAL AND AUDIBLE)
Gas Supply Pressure, Airway Pressure limits, Minute
Volume limits, Battery status, APNEA, Breathing Circuit
Integrity, Leakage and Blockage
AUDIBLE SILENCE Yes, 120 second max
DIMENSIONS (MM) 250 x 200 x 155
WEIGHT (KG/LBS) WITH/WITHOUT BATTERY 2.4/1.77 | 5.29/3.9
INTERNAL VOLUME OF THE COMPLETE
RESPIRATORY SYSTEM (REUSABLE AND
DISPOSABLE)
approx. 690 ml without mask
approx. 800 ml with mask
DEAD SPACE OF PATIENT VALVE WITH ELBOW Approx. 35 ml
COMPLIANCE (DISPOSABLE) HOSE SYSTEM 16.6 ml/kPa
RESISTANCE OF PATIENT HOSE SYSTEM
(INHALATION AND EXHALATION):
Less than 6 cmH2O at 60 l/min & Less than 6 cmH2O at 30
l/min
ENVIRONMENT
CONDITION
Ventilator Operating - 18oC to +50oC, Rh: 15% to 95%
Storage - 40oC to +60oC, Rh: 15% to 95%
Battery Pack
Charge 0oC to +40oC
Discharge - 20oC to +60oC
Storage - 20oC to +35oC, low humidity and no corrosive gas
atmosphere.
Patient Circuit Operating - 18oC to +50oC, Rh: 15% to 95%
Storage - 20oC to +60oC, Rh: 15% to 95%

Other machines similar to Generic e700 Ventilator

1
Location : AMERICA North (USA-Canada-Mexico)
1
Location : AMERICA North (USA-Canada-Mexico)
1
Location : ASIA (North East)
1
Location : ASIA (North East)