Electrovert Omniflo 7
EUROPE (Western and Northern)
Electrovert Omniflo 7 in Excellent conditie.
Vintage: 2002
Features:
- Seven (7) heating zones (seven top and seven bottom forced convection heaters).
- One piece cast aluminum panel heaters with embedded heating elements.
- One (1) high volume forced convection blower in top and bottom zones 1 to 5. Zones 6
and 7 have two (2) forced convection blowers each on the top and
one (1) forced convection blower each on the bottom.
- Three (3) speed settings for blowers, providing approximately 100%, 75%,
and 50% of convection flow. (Zone 1 blowers can be independently locked to low
speed via software to reduce the total nitrogen consumption and oxygen ppm levels.)
- Blower failure detection (including blower power failure) with feedback to computer
and on-screen warning.
- One (1) mechanical power lifts with ratchet clutch to provide computer controlled
automated opening and closing of external hood and upper part of
heating chamber tunnel, allowing full access to interior.
- Multifunctional custom extrusion tunnel walls providing captive hardware
mounting slots, integral nitrogen feed line, positive chamber sealing,
and thermocouple wireways.
- Access to cooling zones is independent of heated chamber section.
- Two (2) cooling zones (top cooling only).
- One (1) high volume forced convection blower in each top cooling zone.
- Three (3) speed settings for blowers, providing approximately 100%, 75%,
and 50% of convection flow. (Blower speed settings are independent between
cooling zones, providing adjustable cooling rates. Cooling Zones 2 &
3 also have on/off capability.)
- Cooling Zone 1 (Exhaust/Cooling module) includes two lip vents with
one cross-flow blower in between; first vent goes to exhaust system;
second vent recirculates via plenum to blower inlet to
reduce exhaust system requirements.
- Cooling Zone 2 includes one lip vent with one cross-flow blower; flow inlet recirculates
via plenum to blower inlet to reduce exhaust system requirements.
(Flow inlet draws ambient air for maximum product cooling).
- Thermocouple in Cooling Zone 1 to monitor cooling zone temperature;
user selectable alarm parameters. (Thermocouple monitors forced gas
convection temperature.)
- Mesh Belt conveyor; 304 stainless steel
- DC motor with closed-loop speed control; pulse feedback from digital shaft encoder
- Product input photocell for on-screen product monitoring and
recipe specific work-in-process tracking
- Conveyor direction: left-to-right