Drager Oxylog 2000 Transport Ventilator
AMERICA North (USA-Canada-Mexico)
Drager Oxylog 2000 offers a time-cycled, and volume-constant transport
and emergency ventilator for patients. It has a tidal volume that starts at 100 mL.
In addition to its classic CMV / IPPV mode,
the Oxylog 2000 ventilator also offers A/C / SIPPV together with
the spontaneous modes Including SIMV and CPAP.
The Oxylog 2000 Ventilator has a flow sensor delivering accurate measurement
on a real-time basis.
It also features an integrated PEEP valve that can be adjusted finely from 0
to 15 mbar per cm of H2O and allows for the incremental adjustments
for the breath-time ratio between 1:3 and 2:1.
Oxylog 2000 ventilator has an analog airway pressure gauge
and Liquid Crystal Display having 2 lines, giving physicians important data such
as actual frequency, plain text alarms, actual tidal volume and other parameters.
The clear design of the Oxylog 2000 ensures safe operations
and optimal handling leaving your hands and eyes free for monitoring
and treating your patient. It also allows for up to six hours of battery operation,
giving reliability and independence from the supply of electricity during this period.
The compact design of this device along with its other features like shock resistance,
electronic irradiation protection, and a splash guard make it one
of the most advanced ventilators available for physicians to treat
and monitor emergency medical events with confidence and ensure better prognosis.
The Drager Oxylog 2000 is also amongst the latest in the category
of advanced emergency ventilators. It provides a higher flexibility to physicians
to adapt ventilation based on the specific needs of the patient’s health status.
It also includes features that enable pressure support and
non-invasive ventilation modes.
These features can help physicians provide support to patients
with breathing difficulties.
Drager Oxylog 2000 is also designed to help prevent intubation at earlier stages.
It can help in controlling and monitoring the details of ventilation
and improve care provided to the patient. It also features intuitive operations
with an easy-to-read display to help physicians focus on the patient.
Key features of the Drager Oxylog 2000:
Helps to optimize comfort and care of patients
Excellent reliability and performance
Intuitive user interface that helps in controlling life-threatening situations
Ergonomically designed transportation solutions
Provides flexibility to adapt as per the patient’s needs
Provides a combination of supportive and controlled ventilation
Compact design
Features a flow sensor that is positioned closer to the patient for more accurate measurements of the minute volume on a real-time basis
Has an integrated PEEP valve that can be adjusted finely between 0
and 15 mbar per cm of H2O,
Offers shock resistance, electronic irradiation protection, and a splash guard
Equipped with an analog airway pressure gauge and Liquid Crystal Display
with two lines, showing important data including actual frequency,
plain text alarms, actual tidal volume, and other parameters
Allows an incremental adjustment of the breath-time ratio between 1:3 and 2:1
Provides up to six hours of battery operation