Menu

Drager Apollo Anesthesia Machine

Ref : 2684156-14-W
Condition : Used
Manufacturer : Drager
Model : Apollo Anesthesia Machine
Year(s) : -
Quantity : 1
Location : Seller or machines location:
AMERICA North (USA-Canada-Mexico)

Condition: Certified Refurbished
Warranty: 90 Days
Integrated breathing system eliminates external hoses and clutter
Fully automatic self-test lasts approximately three minutes
Enhanced troubleshooting with clear text directions
Ventilation technology to support patients of any age and acuity

Drager Apollo Anesthesia Machine Features
Advanced Ventilation: It has the ventilation technology to
support patients of any age and acuity.
The E-Vent plus servo controlled high-speed piston ventilator
works with great precision to supply a maximum peak flow far
in excess of any bellows ventilator, resulting in the kind of performance previously only seen in the ICU. Additionally, unlike a bellows ventilator, it requires no drive gas.
The very short response time has clear physiological benefits
for your patients, while the digital precision helps you make
the most of the latest ventilation modes.
Unique Low-Flow Wizard: Designed to support the user by
providing optimal low and minimal flow settings.
The consistent use of low-flow anesthesia techniques can
significantly reduce the cost of inhalation anesthetic agents.
Reducing the fresh gas flow from 3 L/min to 1 L/min can
result in anesthetic agent savings of up to 50%.

Automated Startup:
Simple straightforward startup makes it easier for the staff and
provides complete information on device status.
Enhanced troubleshooting with clear text directions.
Integrated breathing system eliminates external hoses and
clutter, reducing the risk of misconnection and disconnection.
Fully automatic self-test lasts approximately three minutes,
reflects the results to the user, and makes results available to
the user at any time.

Monitoring:
Standard: Inspiratory and expiratory concentration of O2, N2O,
CO2 as well as anesthetic agents (Halothane, Enflurane,
Isoflurane, Sevoflurane, Desflurane); Minute volume (MV) and
Tidal volume (VT); Breathing frequency;
Peak pressure, plateau pressure, mean pressure, PEEP;
Patient compliance CPAT.
Optional: Functional oxygen saturation (SpO2).
The following parameters maybe displayed as waveforms:
Standard: Concentration of CO2, O2, as well as anesthetic agents, airway pressure, inspiratory and expiratory flow.
Optional: Plethysmogram; Bar graph display of volumeter and
tidal volume; Virtual flow tubes for O2, AIR, N2O;
Display of graphical trends and numerical lists of
measured values; AutoSet for alarm limits.

Specifications
Drager Apollo Anesthesia Machine Specifications
Weight: 365 lb (165 kg) without vaporizers and gas cylinders.
Dimensions: 59" (H) x 33.5" (W) x 31.5" (D)
(150 cm x 85 cm x 80 cm).
Power: 200 W, typically.
Operating Voltage: 100 to 127 VAC (-15% + 10%), 45 to 65 Hz.
Integrated Power Backup: At least 30 min, typically 90 min;
Depending on ventilation parameters.
Ventilator E-Vent plus: Electrically driven and
electronically controlled, fresh gas decoupled.

Ventilation Modes:
Standard: Manual, spontaneous, Volume Mode, Pressure Mode.
Optional/Synchronization: Pressure Support (PS).
Pressure Limitation PMAX (in Volume Mode):
(PEEP + 10) up to 70 cmH2O.
Pressure Limitation PINSP (in Pressure Mode):
(PEEP + 5) up to 70 cmH2O.
Trigger: 0.3 to 15 L/min.
Tidal Volume VT (compliance compensated) (in Volume Mode):
Standard: 20 to 1400 mL.
With Advanced Ventilation option: 5 to 1400 mL.
Breathing Frequency: 3 to 100 bpm.
Inspiration Time (TINSP): 0.2 to 6.7 s.
Inspiration/Expiration Time Ratio (I:E): 5:1 max.
Plateau Time (TIP:TINSP): 0 to 60%.
Inspiratory Flow (in Pressure Mode): 150 L/min max.
PEEP:
In Volume Mode: 0 to 20 cmH2O (max. PMAX - 10 cmH2O).
In Pressure Mode: 0 to 20 cmH2O (max. PINSP - 5 cmH2O).
Fresh-Gas Flow: 0 to 10 L/min for each gas
(oxygen, air, nitrous oxide).
TSLOPE (in Pressure Mode and Pressure Support): 0 to 2 s.
Total System Leakage: Less than 150 mL/min at
30 cmH2O (automatic leak test).
O2 Flow Control: Sensitive ORC Function: At least 21 Vol.-% with
N2O as carrier gas.
O2 Flush: Greater than 35 L/min.
Serial Interface: 2 x RS 232.
Protocol: Medibus, Medibus X.
Absorber Volume (reusable canister): 1.5 L.