Digital, Dr, GE AMX IV-Plus Portable X-Ray
AMERICA North (USA-Canada-Mexico)
With Canon CXDI-55C Detector
Condition Refurbished
Features
CANON 14X17 Wired Flat Pannel Detector CXDI-55C
Color Touch Screen
MX-75 275k HU X-ray tube with a .75mm focal spot
GE AMX-IV collimator
High-quality image
Forward and reverse variable speed
Completely mobile
LED display
Operates at full power with no power connection
24 kVp stations
30 mAs stations
100 mA constant
kVp 50 - 125
mAs 0.4 - 320
SPECIFICATIONS
Physical Weight & Dimensions
Height: 76 inches (1,930 mm)
Width: 25-3/16 inches (640 mm)
Depth: 45-3/8 inches (1,153 mm)
Weight: 1,050 lbs (477 kg)
Battery
Nine 12.9 volt batteries connected in series provide approximately 116 volt at full charge.
Battery capacity is approximately 20,000 mAs at 100 kVp when fully charged
and under specific conditions.
Actual mAs capacity depends on the condition of the batteries, use of collimator lamp,
electric brakes, rotor, and distance driven.
Movements
(tube vertical movement measured at the focal spot)
Range: At least 52.5" (1,334 mm)
Lowest position: 26.1" (663 mm) maximum from floor
Highest position: 78.6" (1,996 mm) minimum from floor
Horizontal movement measured at focal spot relative to column face: 24" (610 mm) minimum to 40" (1,016 mm) maximum
Tube column rotation measured from horizontal latch: 360°
Tube and yoke rotation around horizontal arm measured from tube port down position: Range (360°), detent locations (0, ±90°, ±180°)
Tube trunion rotation measured from tube port down position: Range (120°), forward (110°), backward (10°), detent (0°, 90°)
Collimator rotation measured from the front of the collimator with the tube port facing down: Range (180°), right (90°), left (90°), detent (0°, 90°)
Drive Speeds
Speed 1: Drive speed with horizontal arm secured for support - 264' (6,705 mm) per minute ±25%
Speed 2: Maneuvering speed with horizontal tube arm removed from the transport latch - (30% to 60% of drive speed)
Drive speed is measured on a smooth, hard and level surface.
Speed will be reduced by inclines, carpeted or soft surfaces.
Reproducibility
Coefficient of variation of radiation output is less than 0.045 for successive exposures having constant technique factors.
Collimator
Minimum source to skin distance is limited to more than 30 cm by the skin spacers
at the beam exit of the collimator.
Full 17" × 17" (43 cm x 43 cm) radiographic coverage at 40" (1.02 mm) source to image distance.
Minimum inherent filtration of 2.0 mm aluminum equivalent at 100 kVp.
Light Filed Intensity
The average illumination at a distance of 100 cm (39.37") from the focal spot shall be 16 foot candles (170 lux) or more.