8100 Poet Plus Vital Signs CO2 Veterinary Monitor - Preowned in Good Condition

VENDOR DESCRIPTION
Poet Plus® 8100 is the perfect choice for busy departments demanding maximum flexibility, unsurpassed ease of use, and accurate, reliable performance. Respond to every monitoring need, from standard vital signs to conscious sedation. Monitor adults, pediatrics, and neonates in virtually every department, at bedside or in transit. The Poet Plus 8100 mounts quickly and easily to walls, roll stands, and bedrails.


With the compact, lightweight Poet Plus 8100, you focus on your patients, not your monitor. The innovative user interface with simple, one-level menus and dedicated function keys ensures super-fast set-up. The big, bright display with large numerics is easily seen, even from across the room.





FEATURES


Easy-to-read 10.4" active TFT color display

View up to 6 waveforms simultaneously.

Easy to learn, easy to use menus, dedicated function keys, and simplified controls

Smart battery management with rechargeable "hot-swappable" sealed lead acid batteries

Lightweight design and versatile mounting options

Adapts readily to department and transport requirements





SPECIFICATIONS


System Outputs

Communication Ports: RS-232 compatible; DB9, analog mini-din
Nurse Call: contact switch, stereo jack 3.5 mm, length 14 mm standard
Defib / Sync: BNC connector

Video Port: high density D-sub 15-pin



Recorder

Type: Thermal Line Printer

Paper speed: 12.5, 25, 50mm/sec



Mechanical

Weight: Base unit without batteries: 12 lbs, 5.45kg

Size: Base unit: 13.25 "(H) x 12.5" (W) x 8.75 "(D)



Power Requirements

Voltage: 100, 120, 220, 240 VAC, 50/60 Hz

Consumption: 35 W, typical

Batteries: 2, Sealed Lead Acid, life: 2 hr, typical recharge time: 4.5 hours



ECG

Connectors: 3- or 5-lead

Leads: User-selectable; I, II, III, aVR, aVL, aVF, V (5-lead); I, II, or III (3-lead)

Gain Selection: 1/2mV, 2mV, 4mV

Frequency Response:
- Diagnostic: 0.05 to 100 Hz (-3db);
- Monitor: 0.5 to 40 Hz (-3db)
Sweep Speed: 12.5, 25, 50mm/sec

Electrosurgery Protection: Yes

Defibrillator Protection: Yes

Pacer Detection/Rejection: Yes



Non-Invasive Blood Pressure

Technique: Oscillometric measure upon inflation

Automatic Measurement Cycles: 2, 3, 5, 10, 15, 30 min; 1, 2, 4 hr

Measurement Range: Adult: 30 to 300mmHg; Neonate: 0 to 150 mmHg

Resolution: 1mmHg

Transducer Accuracy: ±2mmHg or ±2% of reading, which ever is greater, over full range

STAT mode: 5 min of consecutive readings



Pulse Oximetry

Range: 1% to 99%

Resolution: 1%

Accuracy: 70% to 99% range: ±2%; 50% to 69% range: ±3%;