Baxter Colleague CX Infusion Pump
AMERICA North (USA-Canada-Mexico)
Baxter Colleague CX Infusion Pump
Product Specifications
Ac power Requirements:
100-120 VAC, 60Hz
Leakage Current:
Less than 300 u amps earth leakage (tested per UL 2601)
External Fuses:
1.6 amp Type T (time delay) 250V
Power Cord:
2.9 m (9 feet) long with integrally molded hospital grade plug
Battery Supply System:
5 hours operating time at 100 mL/hr (fully charged new batteries) 8 hours to recharge to 80% of capacity. Internal charge system recharges batteries whenever the device is connected to an AC outlet
Range of Programmable Flow Rates:
Primary Infusion: 0.1 to 99.9 mL/hr in 0.1 mL/hr increments
1 to 1200 mL/hr in 1 mL/hr increments
Piggyback Infusion: 0.1. to 99.9 mL/hr in 0.1 mL/hr increments
1 to 500 mL/hr in 1 mL/hr increments
Note: Rate limits can be configured for values less Than those stated above.
Volume to be Infused:
0.1 – 99.9 mL in 0.1 mL increments 1- 9999 mL mL/hr in 1 mL increments
Note: Volume to be Infused limits can be configured for values less than those stated above
KVO:
0.1 – 5 mL/hr in 0.1 mL increments (configurable option) or programmed rate whichever is less.
Priming rate:
500 mL/hr (to be used only when not connected to patient)
Advance Air Rate to Advanced an Air Bubbles:
At the same rate programmed for the current primary or piggyback infusion.
Air Bubble Setting:
Measured accumulations of approximately
25 microliters
50 microliters
100 microliters 150 microliters
The Air Bubble Setting is a configurable option.
Auto Restart:
Allows the pump channel to automatically restart if an occlusion is relieved within one minute after detection. This configuration option allows 0 to 9 restarts before manual intervention is required.
Nominal Downstream:
Alarm sensitivity is a configurable option. Rate range in mL/hr
200
6 psig (Minimum)
11 psig (Moderate)
15 psig (Maximum)
Device Size:
Approximately 10″ H x 7.75″ W x 7.75″ D
(254 x 197 x 197 mm)
Not including clamp knob or power cord
Device weight:
Approximately 10.4 lbs (4.7kg)
Environmental Operating Limits:
59º F – 100º F (15º C – 38º C)
Environmental Storage and Transport Limits:
-20º F – 135º F (-29ºC – 57º C), 10-100% Reliable Humidity including condensation, 500-1060 hPa Barometric Pressure
Ground Impedance:
Less than 0.2 ohms (tested per UL-2601)
Solution Container Height:
Pump will operate at all programmable flow rates with a solution container height ranging from -36 to +48 inches. Container height is measured from the pump channel selected for use.
Interfaces:
Attachment to a remote nurse call system A variety of systems exist which enable alert and alarm conditions to be transmitted to a remote location via the communications port on the rear panel assembly of the pump. See the service manual for additional information.
Features:
Preset Label Library
User Defined Label Library
Dose Calculator
View Limits Soft Key
Programmable Personalities