Assens ST-100 Portable Dielectric Oil Strength Tester,Oil BDV Tester
ASIA (China - Taiwan - HKG)
Introduction:
ST Dielectric Oil Test kit is apply for speedy and accurate testing of dielectric strength of transformer and circuit breaker oil under test room condition in accordance with IEC international standard.
Functions:
1.Breakdown test of user-defined
2. Proof test
3. IEC156/IS6792/BS5874/
4. ASTM D1816 standard test
5. ASTM D877 standard test
6. 5 minutes standard test
7. Manual test
8.Temperature measurement
9. Calibration interface for customers
10. Unloading data to PC and making word report automatically.
11. Result print
Features:
1. withstand voltage test in the range of 0 ~ 80KV.
2. Large-screen LCD.
3. Simple operation
4.Store 100 experimental results, and display the currentenvironment temperature and humidity.
5. The whole process easy to control.
6.With overvoltage, overcurrent, limiting protection, in order to ensure the safety operation.
7.With a temperature measurement display function and system clock display.
8.Standard RS232 interface.
9. PC application software is provided to upload test data to make WORD test report
10. Menu management, data input simple and convenient.
11. The instrument adopts intermediate frequency induction heating and PID temperature control algorithm. The oil cup and the heating body are non-contact, heating evenly, fast and easy to control.
12. Empty electrode cup calibration function. Measure the capacitance and dielectric loss factor of the empty electrode cup to judge the cleaning and assembly status of the empty electrode cup. The calibration data is automatically saved to facilitate accurate calculation of relative permittivity and DC resistivity.
13. The instrument adopts intermediate frequency induction heating and PID temperature control algorithm. The oil cup and the heating body are non-contact, heating evenly, fast and easy to control
Specifications:
1 Output voltage AC 0~80KV/AC 0~100KV
2 Rate of voltage rise 2KV/s±10%
3 Measuring precision 3%RDG+0.3%FS
4 Test times setting 1~9
5 Mixing time setting 0~99 second
6 Waiting time setting 0-9 minute 59second
7 Maximum storage capacity 100 groups of test data
8 Test standards IEC60156
9 Display 256*128 LCD
10 Rated power supply AC 220V±10% 50Hz/60Hz
11 Environment temperatures 0-50°C
12 Relative humidity ≤80%RH
13 Size 530×550×530mm
14 Weight 48kg