Agilent 1100 HPLC G1314A Variable Wavelength Detector

Ref : 2282760-18-CP
Condition : Used
Manufacturer : Agilent
Model : 1100
Short Description : HPLC G1314A Variable Wavelength Detector
Year(s) : -
Quantity : 1
Location : Seller or machines location:
AMERICA North (USA-Canada-Mexico)
Last check : 15 Jul. 2022

The Agilent 1100 HPLC G1314A Variable Wavelength Detector lowers detection limits
with simplified optics for high sensitivity, low baseline drift, and wide linear range.
This wide linear range allows for reliable simultaneous quantitation of main and side products and impurities.
The Agilent 1100 VWD’s minimum baseline noise gives it the highest baseline stability for the lowest detection limits.
This VWD offers programmable wavelength switching for sensitivity and optimized selectivity optimized to each analyte’s elution,
along with stop-flow wavelength scanning for quick wavelength optimization.

Key features include:
Deuterium lamp for highest intensity and lowest detection limit over a wavelength range of 190 to 600 nm;
optional flow-cell cartridges depending on application needs; easy front access to lamp and flow cell for fast replacement;
and built-in holmium oxide filter for fast wavelength accuracy verification.

INCLUDED:
The Agilent 1100 HPLC G1314A Variable Wavelength Detector includes:
> Firmware version A.06.54 (Can be changed upon request)
> Flow Cell
> UV Lamp
> Calibration Report
> Lab Advisor Diagnostic Report
> Lan Cable / Power Cord
> Operator's Manual
> Full 90 Day Parts and Labor Warranty

Specifications:
Detection type Double-beam photometer
Light Source Deuterium lamp
Wavelength Range 190 - 600 nm
Short term noise (ASTM) Single and Multi-Wavelength ± 0.75 × 10-5AU at 254 nm
Drift 3 × 10-4AU/hr at 254 nm
Linear Absorbance range > 2 AU (5%) upper limit
Wavelength accuracy ± 1 nm
Slit width 1, 2, 4 , 8, 16 nm
Band Width 6.5 nm typical
Diode Width < 1 nm

Flow Cells :
Standard: 14-µl volume, 10-mm cell path length and 40 bar (588 psi) pressure maximum
High pressure: 14-µl volume, 10-mm cell path length and 400 bar (5880 psi) pressure maximum
Micro: 1-µl volume, 5-mm cell path length and 40 bar (588 psi) pressure maximum
Semimicro: 5-µl volume, 6-mm cell path length and 40 bar (588 psi) pressure maximum