220 Burner
AMERICA North (USA-Canada-Mexico)
Brand SIB SIBER
LPG/Natural Gas Fuel
Minimum Calorie Power: 26,400 - 8250 kcal/Nm3
Fuel Feeding Power: Max 500 mbar
Thermal Potential Minimum: 13 kw
Thermal Potential Maximum: 256 kw
Temperature of incoming process air: 20-35 degrees Celsius (68 - 95 Fahrenheit)
Temperature of outgoing process air: 130 degrees Celsius (266 Fahrenheit)
Type of control: Modulating
Gas ramp connection union: 1" diameter
Installed electric power: .1 Kw
Electrical supply to auxiliary parts: 115v - 60 hz
Intelligent terminal board electrical supply: 24v dc
Power circuit electrical supply: 115v - 60 hz
Ignition: Automatic with electrode
Flame detection: Ionized electrode
Documentation, electrical schematics & drawings included